A data center equipment maker was moving to a denser 2U chassis and needed 5,000 enclosures delivered in seven weeks, with slide rails that mated without rework.
Project Background
The chassis used 1.2 mm SGCC galvanized steel with 14 bends per side, a 19-inch rack profile, and an EMI gasket channel along the front opening. Tolerance stack across the rail mounting faces had to stay within ±0.15 mm to keep server blades sliding freely.
The Engineering Challenge
With 14 bends, a ±0.5° angle error compounded into more than 1 mm of positional drift at the rail faces. The EMI gasket channel was also sensitive to powder coating thickness: coating build-up on the grounding pads raised resistance above the 25 mΩ limit and caused intermittent EMC test failures.
We corrected the issue by re-datuming the bend program, adding a dedicated gauging step after the fourth bend, and masking all grounding pads before coating. Gasket channel depth was verified with a go/no-go gauge on every part.
Impact and Results
Rail-face tolerance held at ±0.12 mm, first-pass assembly yield reached 97.5%, and grounding resistance measured under 10 mΩ. All 5,000 units shipped in seven weeks with zero rework at the customer’s line.